[2021] HPE2-T37 Answers HPE2-T37 Free Demo Are Based On The Real Exam [Q22-Q41]

Share

[2021] HPE2-T37 Answers HPE2-T37 Free Demo Are Based On The Real Exam

HPE2-T37 [Dec-2021 Newly Released] Exam Questions For You To Pass


HP HPE2-T37 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Architect and design a data center management solution using the HPE OneView
Topic 2
  • Describe industry standard data center infrastructure management technologies
Topic 3
  • Provision Hybrid IT infrastructure using HPE OneView
  • Install and configure HPE OneView and related elements
Topic 4
  • Monitor and troubleshoot common Hybrid IT infrastructure issues using HPE OneView

 

NEW QUESTION 22
As a part of troubleshooting, you have to reinstall the same version of the firmware on an HPE Synergy Compute Module. Click the area within the Firmware section of the server profile that will allow you to install the same firmware version.

Answer:

Explanation:

 

NEW QUESTION 23
You want to update the firmware for only two HPE Synergy Virtual Connect SE 32Gb FC Modules of a large environment. From which level must this procedure be initiated?

  • A. Logical Enclosure
  • B. Server Profile
  • C. Logical Interconnect
  • D. Logical Interconnect Group

Answer: A

 

NEW QUESTION 24
Your customer asks you if it is possible to perform HPE Synergy initial setup remotely. How should you respond?

  • A. HPE Synergy cannot be deployed remotely, as Initial setup must be performed using a local console connection.
  • B. HPE Synergy can be configured remotely through a secure connection to the FLM if this option was enabled In the factory.
  • C. Remote HPE Synergy Installation can be done only if an additional set of the services was purchased together with hardware platform.
  • D. Remote HPE Synergy setup is possible if HPE Composer 2 is used and a DHCP server Is available in the management network.

Answer: B

 

NEW QUESTION 25
You try to add an HPE Primera array to HPE OneView, but you get a connectivity error. However, you can connect to the array using SSMC. What should you verify before adding HPE Primera to HPE OneView?

  • A. whether array management using HPE OneView is enabled in SSMC.
  • B. whether there are at least two Fibre Channel networks defined in HPE OneView.
  • C. whether WSAPI service is enabled on HPE Primera array.
  • D. whether the appropriate license for HPE Primera Is available in HPE OneView.

Answer: C

 

NEW QUESTION 26
You ate implementing an HPE Synergy solution with multiple frames in one management ring. Image Streamer is not a part of this solution. How can an IPv4 address pool defined by the administrator be used In HPE OneView?

  • A. to provide static IP addresses for an operating system running on a Compute Module
  • B. to provide static IP addresses for Logical Interconnects and Logical Enclosures
  • C. to provide static IP addresses to IL0 and interconnect modules if applicable
  • D. to provide static IP addresses for storage systems managed in HPE OneView

Answer: A

 

NEW QUESTION 27
Refer to the exhibit.

You discovered that one of the profiles is not compliant with the server profile template. What could cause this profile to be inconsistent with the server profile template?

  • A. Changes to the server profile were implemented directly on the server profile.
  • B. The server was powered off or rebooted recently and IL0 did not reconnect to HPE OneView.
  • C. HPE OneView was restored from a backup that created ^consistency with the server profile template.
  • D. Network connectivity for HPE Synergy Compute Module was changed outside HPE OneView.

Answer: D

 

NEW QUESTION 28
Which HPE components can be managed using HPE Composer? (select two.)

  • A. HPE Synergy 480 Compute Modules
  • B. HPE Synergy Virtual Connect SE 32Gb FC Module
  • C. HPE B-series SN6600B Fibre Channel Switch
  • D. HPE MSA 2062 Storage Array
  • E. HPE Superdome Flex 280

Answer: B,C

 

NEW QUESTION 29
Refer to the exhibit.

Your customer created multiple networks in HPE OneView, but only Eth-1 is available to be used within a server profile. What is a likely cause of this situation?

  • A. The other networks are configured with a purpose other than General or Management.
  • B. The other networks are not added to the Logical Interconnect Group configuration.
  • C. The other networks are not configured with the required Smart Link parameter.
  • D. The other networks have Private Network' selected, which hides them from Compute Modules.

Answer: D

 

NEW QUESTION 30
What is required to add remote frame link topology to HPE OneView?

  • A. Multi-site licenses must be added to HPE OneView and activate for all available HPE Synergy frames.
  • B. Management ports of the remote frame link topology must be connected to the management LAN.
  • C. The HPE OneView certificate from the primary site must be added to HPE OneView in the remote site.
  • D. The IP address assigned to HPE Composer installed in a remote site must be registered in a primary site.

Answer: A

 

NEW QUESTION 31
After replacing a failed Compute Module, you notice the server profile Is not automatically assigned to the replaced server hardware. What can cause this issue?

  • A. The enclosure group has to be updated to match the original enclosure group.
  • B. The replacement server has more memory or CPUs than broken machine.
  • C. Server profile affinity is configured to Device Day + server hardware.
  • D. IL0 firmware of the replacement server is different than firmware in broken server.

Answer: D

 

NEW QUESTION 32
Which statement about a Logical Enclosure for HPE BladeSystem is Hue?

  • A. A logical enclosure can have between 1 to 5 HPE BladeSystem c7000 enclosures.
  • B. A logical enclosure can contain a mix of HPE BladeSystem c7000 and C3000 enclosures.
  • C. A logical enclosure is created automatically, and it is always based on a single enclosure.
  • D. A logical enclosure must be created only for monitored HPE BladeSystem C700O enclosures.

Answer: C

 

NEW QUESTION 33
Which statement about access to HPE Onboard Administrator is true when an HPE BladeSystem enclosure is added to HPE OneView?

  • A. It is blocked when HPE BladeSystem enclosure is monitored using HPE OneView.
  • B. It is enabled only when an HPE BladeSystem enclosure is monitored using HPE OneView.
  • C. It is enabled when an HPE BladeSystem is either managed or monitored using HPE OneView.
  • D. It is blocked when an HPE BladeSystem enclosure is managed using HPE OneView.

Answer: B

 

NEW QUESTION 34
What step must be taken to add an HPE SuperDome Flex to an existing OneView environment

  • A. HPE Superdome Flex complex can be added by adding base chassis of this complex.
  • B. Each HPE Superdome Flex chassis must be added Individually using BMC IP.
  • C. A Rack Management Controller must be added to HPE OneView.
  • D. HPE Superdome Flex can be added to HPE OneView after at least one nPAR is created.

Answer: C

 

NEW QUESTION 35
Which components require an HPE OneView license for management?

  • A. HPE Virtual Connect modules
  • B. HPE Primera and HPE 3PAR
  • C. HPE Apollo XL 170r
  • D. Brocade and Cisco SAN Manager

Answer: A

 

NEW QUESTION 36
Your customer wants to optimize GenlO servers for a virtualization workload by configuring all of them with a specific workload profile in the BIOS. All of the servers are managed using HPE OneView.
How can this task be completed?

  • A. Set a specific workload profile using IL0 interface for each individual server.
  • B. Set a specific workload profile for all managed servers as an HPE OneView global setting.
  • C. Set a specific workload profile within server profile template and update all profiles.
  • D. Set a specific workload profile within Logical Interconnect Group and update all servers.

Answer: B

 

NEW QUESTION 37
Your customer plans to use HPE OneView to manage a small environment based on HPE ProLiant servers that includes G7 and Gen 10 systems. What should you explain to this customer?

  • A. HPE Management Agent must he installed for for HPE ProLiant Gen 10 servers.
  • B. HPE ProLiant Gen 10 servers do not need an HPE OneView license.
  • C. Not all of the features will be available for HPE ProLiant G7 systems.
  • D. HPE ProLiant G7 and Gen10 cannot be managed using the same appliance.

Answer: B

 

NEW QUESTION 38
......

New 2021 Realistic Free HP HPE2-T37 Exam Dump Questions & Answer: https://www.exams4collection.com/HPE2-T37-latest-braindumps.html

HP HPE2-T37 Exam: Basic Questions With Answers: https://drive.google.com/open?id=1YTc8VP_nSJ38jJnWb0m3Rwpi7PggBOqP