[2024] Get Top-Rated Cisco 300-615 Exam Dumps Now [Q127-Q152]

Share

[2024] Get Top-Rated Cisco 300-615 Exam Dumps Now

Passing Key To Getting 300-615 Certified Exam Engine PDF

NEW QUESTION # 127
A customer reports that the Chassis Management Controller fails to receive chassis information from Cisco UCS Manager Which set of steps resolves the issue?

  • A. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.
  • B. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least two physical cables between the IOM and fabric interconnect function properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.
  • C. 1) Verify that the IOM firmware and Cisco UCS Manager are at the same software level.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status
    4) Reseat the affected IOM.
  • D. 1) Verify that the IOM firmware and Cisco UCS Manager are at different software levels.
    2) Verify that at least one physical cable between the IOM and fabric interconnect functions properly.
    3) Check for runtime link down status.
    4) Reseat the affected IOM.

Answer: C


NEW QUESTION # 128
A user reports that they cannot reach from a UCS server to an FC Storage array. Which command is used to test communication between an FCF and a target?

  • A. fcroute
  • B. ping
  • C. fcping
  • D. traceroute

Answer: C


NEW QUESTION # 129
A network engineer discovers a DNS resolution problem on a device that is using the Cisco Nexus Bash shell.
The device name is app with an IP address of 10.10.10.1. The primary server IP address is
172.16.10.1 and the secondary server IP address is 172.16.10.2. When the abc.com resolution fails, it should attempt to use efg.com.
Which settings must be added to resolv.conf file to resolve the issue?

  • A.
  • B.
  • C.
  • D.

Answer: B

Explanation:
https://www.cisco.com/c/en/us/support/docs/switches/nexus-9000-series-switches/213959-nx-os-bash-shelldns-configuration.html


NEW QUESTION # 130

Refer to the exhibit. A new Cisco Nexus 5548 Switch connects to a network. SAN switching is configured on the switch. The switch fc2/10 NP uplink is shown in the exhibit. Which action ensures that fc2/10 is in an up state?

  • A. Enable NPIV on the upstream switch that connects the port.
  • B. Replace the SFP port module in fc2/10.
  • C. Configure the admin port type E on the upstream switch that connects the port.
  • D. Configure the BB_credit buffers on the upstream switch that connects the port.

Answer: A

Explanation:
Section: Storage Network


NEW QUESTION # 131
Refer to the exhibit. When an engineer inserts 8-Gb FC SFP port 15 on a Cisco UCS Fabric Interconnect, the port fails. What is a possible cause of the issue?

  • A. Port 15 is missing a license.
  • B. Port 15 is configured as an Ethernet port.
  • C. Port 15 is configured for 4-Gb Fibre Channel.
  • D. The polarity of the fiber cable is reversed.

Answer: B

Explanation:
Cisco 8-Gbps Fibre Channel SFP+ modules provide Fibre Channel connectivity for the 2/4/8 Gbps ports.
https://www.cisco.com/c/en/us/products/collateral/storage-networking/mds-9000-series-multilayer-switches/product_data_sheet09186a00801bc698.html


NEW QUESTION # 132
You have an ACI environment with three APICs, two spine switches, and four-leaf switches. You wipe and reboot all APICs first then leaf and spine switches one-by-one and successfully go through the Initial Setuo dialogue on the APIC 1 CIMC KVM console. When you log in to the APIC1 WebGUI, you notice that you do not see any directly connected leaf switches being discovered under Fabric > Inventory > Fabric Membership. What is the cause of the issue?

  • A. The same Fabric Name value should be used before after wiping all devices.
  • B. The leaf nodes were not erased properly, which caused a fabric parameters mismatch with the APIC1.
  • C. Rebooting the APICs and the leaf and spine switches after wiping them is not required.
  • D. You forgot to enter the TEP Pool value during the Initial Setup dialogue on APIC1.

Answer: D


NEW QUESTION # 133
Drag and Drop Question
Drag and drop the commands from the left onto the correct categories on the right.

Answer:

Explanation:


NEW QUESTION # 134
Refer to the exhibit.

Interface fc1/5 is offline. Which action should be taken to troubleshoot the issue?

  • A. Configure the upstream ports and the server ports to be in VSAN 100.
  • B. Update the FLOGI database to contain the FLOGI entries for interface fc1/5 in VSAN 100.
  • C. Update the FCNs database to contain names for VSAN 100.
  • D. Activate the correct zoneset for VSAN 100.

Answer: A


NEW QUESTION # 135
An engineer is troubleshooting a failed DCBX exchange between a server and a Cisco Nexus switch.
Which action allows DCBX to successfully negotiate?

  • A. Enable LLDP.
  • B. Enable ETS
  • C. Enable PFC.
  • D. Enable Cisco Discovery Protocol.

Answer: A

Explanation:
Section: Storage Network
Explanation


NEW QUESTION # 136
Refer to the exhibit.

The EEM script overrides all events in the system policy. What should be added to the script to resolve the issue?

  • A. event-default action statement
  • B. event statement
  • C. environment variable
  • D. configure terminal action

Answer: B


NEW QUESTION # 137
An engineer is troubleshooting a custom AV pair that was created by a client on an external authentication server to map a read-only role for a specific security domain. Which AV pair solves the problem?

  • A. shell:domains=Security_Domain_1//Read_Role_1|Read_Role_2
  • B. shell:domains=Security_Domain_1/Write_Role_1|Read_Role_2
  • C. shell=Security_Domain_1/Read_Role_1|Read_Role_2
  • D. shell:domains=Security_Domain_1/Read_Role_1|Read_Role_2

Answer: A


NEW QUESTION # 138
A system administrator adds two vNICs to an existing service profile that is used to run a vSphere environment to support disjoint Layer 2 network connectivity. However, after the server is rebooted, the host is not accessible on the network Which action resolves the issue?

  • A. Build a new service profile with the desired network configuration
  • B. Create a vNIC placement policy to avoid adapter renumbering
  • C. Remove all existing vNICs and add them in the desired order.
  • D. Add the disjoint Layer 2 VLANs to an existing vNIC rather than adding new vNICs

Answer: D


NEW QUESTION # 139
Refer to the exhibit.

The vPC between switch1 and switch2 does not work. Which two actions resolve the problem? (Choose two.)

  • A. Configure the IP address on the interface.
  • B. Activate VLANs on the vPC.
  • C. Match the vPC domain ID between the two devices.
  • D. Configure one of the switches as primary for the vPC.
  • E. Correct the configuration of the vPC peer link and the vPC peer keepalive.

Answer: C,E

Explanation:
Explanation
Both "vPC peer link" and "Peer keepalive link" are down. So, D is correct.
SW1 is using vPC domain ID 500, which SW2 is using 20. They must match. So, E is correct.


NEW QUESTION # 140
Refer to the exhibit. An integration issue occurs between the Cisco Intersight and Cisco UCS C240 server. The requirements are to install the server OS through virtual media directly from Cisco Intersight, and to be able to perform the task from HQ. However, the 10.1.1.0/24 network is not reachable from HQ. Which action must be taken on UCS C240 to resolve the issue?

  • A. Enable tunneled vKVM from the CIMC.
  • B. Set the connector Access Mode to Read Only.
  • C. Disable the device connector.
  • D. Change the assigned license to be essential.

Answer: A


NEW QUESTION # 141
An engineer is troubleshooting a failed DCBX exchange between a server and a Cisco Nexus switch. Which action allows DCBX to successfully negotiate?

  • A. Enable LLDP.
  • B. Enable ETS
  • C. Enable PFC.
  • D. Enable Cisco Discovery Protocol.

Answer: A

Explanation:
Section: Storage Network


NEW QUESTION # 142
Refer to the exhibit. An engineer is implementing Fibre Channel (FC) switching on a Cisco 9000 Series Switch, but the procedure fails with the message "FC traffic is not being routed through the fabric".

Which action resolves the issue?

  • A. Configure the VSAN ID 10 on the link connected to fc1/12.
  • B. Set the FSPF interface link cost to be less than 30,000 in the IVR path.
  • C. Configure the FSPF for VSAN 10 on the NX9k-01-LAB switch.
  • D. Set the FSPF hello interval on fc12 interface the NX9k-01-LAB switch.

Answer: D


NEW QUESTION # 143
You are configuring a Cisco Nexus 9000 Series Switch. Which configuration can be implemented for VXLAN BGP EVPN?

  • A. QoS classification for the VXLAN traffic on all of the interfaces
  • B. VXLAN BGP EVPN by using an NVE interface in a default VRF
  • C. RACLs on the Layer 3 uplinks for the VXLAN traffic
  • D. DHCP snooping on the VXLAN VLANs

Answer: B

Explanation:
https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/vxlan/configuration/guide/b-cisco-nexus-9000-series-nx-os-vxlan-configuration-guide-93x/b-cisco-nexus-9000- series-nx-os-vxlan-configuration-guide-93x_chapter_0101.html


NEW QUESTION # 144
An engineer upgrades Cisco UCS firmware from release 3.1(2) to release 3.1(3) using Autolnstall. Both fabric interconnects go ofline during the software upgrade installation and issue multiple F SM retries in the DeployPollActivate stage.
Which set of actions resolves the issue?

  • A. Clear the startup version of the default infrastructure and server pack.
    Remove the service pack from the subordinate node.
    Upgrade with the Force attribute through Autolnstall.
  • B. Fix the rights to 666 with the debug plugin on the primary fabric interconnet.
    Save the current configuration on the running fabric interconnect.
    Continue the upgrade on both fabric interconnects.
  • C. Acknowledge the error and reboot the primary fabric interconnect.
    Clear the default firmware version and upload a new one.
    Restart the upgrade process manually.
  • D. Enable the management interface monitoring policy on the fabric interconnects.
    Initiate a configuration backup on both fabric interconnects.
    Commit the pending fabric interconnect reboot activity.

Answer: A


NEW QUESTION # 145
Refer to the exhibit.

vPC between switch1 and switch2 is not working. Which two actions are needed to fix the problem? (Choose two.)

  • A. Configure vPC peer link and vPC peer keepalive correctly.
  • B. Configure IP address on the interface.
  • C. Configure one of the switches as primary for the vPC.
  • D. Activate VLANs on the vPC.
  • E. Match vPC domain ID between the two devices.

Answer: D,E


NEW QUESTION # 146
Refer to the exhibit. A client configures an upgrade of its Cisco Nexus switches that are connected to the Cisco ACI controller, such that the switches are upgraded one at a time. After the upgrade is run, it is discovered that both Cisco Nexus switches were upgraded simultaneously. Which two actions ensure that the switches upgrade one at a time? (Choose two.)

  • A. Configure the "Do not pause on failure and do not wait on cluster health" Run Mode
  • B. Place each leaf switch in a different upgrade group
  • C. Check the "Ignore Compatibility" checkbox
  • D. Choose the "Pause upon upgrade failure" Run Mode
  • E. Select the "Graceful Maintenance" checkbox

Answer: B,E


NEW QUESTION # 147
Refer to the exhibit.

The EEM script is applied in the default VDC to collect the outputs during high CPU utilization on the Cisco Nexus 7000 Series Switch for all VDCs. Which configuration set must be added to the script to fix the issue?

  • A. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
  • B. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli config t switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
  • C. switch(config-apple)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution
  • D. switch(config-apple)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1 switch(config-apple)# action 0.2 cli enable switch(config-apple)# action 0.5 cli switchto vdc Core switch(config-apple)# action 0.8 cli switchto vdc Distribution

Answer: C

Explanation:
Need exact snap shot to confirm the following.
The selection of is due to
SNMP command has the key word "oid".
The command "switchto vdc Core" show run in "enable" mode, not "config t" mode.


NEW QUESTION # 148
A server administrator attempts to change the Cisco IMC KVM certificate to one signed by a private CA, but the certificate is not being accepted. What can cause this process to fail?

  • A. RSA encryption being used in the generation of the certificate.
  • B. using a certificate with a password-protected private key
  • C. AES encryption being used in the generation of the certificate.
  • D. public IP addres of the Cisco IMC not being included in the SAN.

Answer: B


NEW QUESTION # 149
A server fails to boot from the operating system after a RAID1 cluster migration. The RAID remains in an inactive state during and after a service profile association. Which action resolves the issue?

  • A. Remove the local disk configuration policy.
  • B. Use a predefined local disk configuration policy.
  • C. Configure the SAN boot target in the service profile.
  • D. Configure the SAN boot target to any configuration mode.

Answer: B

Explanation:
Section: Storage Network


NEW QUESTION # 150
Refer to the exhibit. The scheduler was configured to save the running-config automatically daily.
However, the scheduler is returning the error presented. Which action resolves the issue?

  • A. Change the file transfer protocol to TFTP in scheduler job
  • B. Use the kstack attribute for copying the configuration file
  • C. Reconfigure the scheduler using the admin user
  • D. Remove vrf management from the command

Answer: A


NEW QUESTION # 151
An engineer configures FCoE between a set of ESXi hosts and a Cisco Nexus 5000 Series Switch. The Converged Network Adapter of the host fails to receive the response from the Cisco Nexus device. Also, the VFC interface is in a down state and the FIP adapter fails to receive 802.1q tagged frames. The host interface is configured for VLAN trunking. Which action resolves the issue?

  • A. Set the bound Ethernet trunk interface to non-FCoE native VLAN
  • B. Activate the reception of Xoff pause frames from the server
  • C. Enable the active STP port state on the bound Ethernet interface
  • D. Configure the UF link as a spanning-tree edge port

Answer: A


NEW QUESTION # 152
......

300-615 exam questions for practice in 2024 Updated 243 Questions: https://www.exams4collection.com/300-615-latest-braindumps.html

300-615 Exam Dumps Pass with Updated Tests Dumps: https://drive.google.com/open?id=1f8TOLlwQsNtBjL4g5EQ9JAJkAiOz1kjg